ELECTRIC STAINLESS STEEL304 BALL VALVE
T25-S2-C
Technical Parameters:
Product size |
NPT/BSP 1/4'' 3/8" 1/2" 3/4" 1" (Optional) |
Maximum working pressure |
1.0MPa |
Circulation medium |
Fluid, air |
Rated voltage |
AC/DC110-230V |
Wiring control methods |
CR202/CR303/CR305/CR306/CR401/CR502/CR703/CR7-04/CR705/CR706 (Optional) |
Static current |
≤500MA |
Open/close time |
≤5S |
Life time |
70000 times |
Valve Body material |
304 Stainless steel |
Actuator material |
Engineering Plastics |
Sealing material |
FKM & PTFE |
Actuator rotation |
90° |
Max. torque force |
2N.m |
Cable Length |
0.5m,1.5m, (Optional) |
Environment temperature |
-15ºC~50ºC |
Liquid temperature |
2ºC~90ºC |
Manual override |
Yes or No (Optional) |
Indicator |
Yes |
Protection class |
IP67 |
Wiring diagram
CR201 Wiring Diagram ( 2 wires control )
RD connect with positive, the BK connect with negative, the valve closed, the actuator automatically power off after in place , the valve remains fully closed position .
BK connect with positive, the RD connect with negative, the valve open, the actuator automatically power off after in place, the valve remains fully open position .
Suitable Working Voltage: DC12V/DC24V
Exceeding the working voltage is forbidden
CR202 Wiring Diagram ( 2 wires control - Spring return in case of the power is failure)
When SW is closed , the valve open. the actuator automatically power off after in place
When SW is open, the valve closed, the actuator automatically power off after in place
Suitable Working Voltage: AC/DC9-35V
Exceeding the working voltage is forbidden
CR303 Wiring Diagram (3 wires control )
RD connect with positive, GR connect with SW & positive
BK connect with negative
When the SW of GR closed, the valve OPEN, the actuator automatically power off after in place , remains fully closed position
·When the SW of GR open, the valve CLOSED, the actuator automatically power off after in place , remains fully open position.
Suitable Working Voltage: DC12V/AC/DC24V/AC/DC110V-230V
CR401 Wiring Diagram (4 wires control )
RD & BK are connected to the power, GY& GR are connected to the controlled wiring.
When the SW is closed , the valve open
When the SW is open , the valve closed
Suitable Working Voltage::AC110V-230V
Exceeding the working voltage is forbidden
CR501 Wiring diagram ( with feedback signal)
RD connect with positive, the BK connect with negative,the valve closed, the actuator automatically power off after in place .
BK connect with positive, the RD connect with negative,the valve open, the actuator automatically power off after in place .
BL & WT are connect when the valve open fully, YW & WT are connect when the valve closed fully
Suitable Working Voltage::DC12V/DC24V
Exceeding the working voltage is forbidden
CR502 Wiring diagram ( with feedback signal)
When SW is closed , the valve open. the actuator automatically power off after in place
When SW is open, the valve closed, the actuator automatically power off after in place
BL & WT are connect when the valve open fully, YW & WT are connect when the valve closed fully
Suitable Working Voltage: AC/DC9-35V
Exceeding the working voltage is forbidden
CR703 Wiring Diagram ( 7 wires control with feedback signal )
RD& GR connect with positive, the BK connect with negative.
SW CLOSED, the valve OPEN, the actuator automatically power off after in place
SW OPEN, the valve CLOSED, the actuator automatically power off after in place.
BL & GY connect with the valve's fully open signal wiring
YW & WT connect with the valve's fully closed signal wiring.
Suitable Working Voltage: DC12V/AC/DC24V
Exceeding the working voltage is forbidden
CR704 Wiring Diagram ( 7 wires control with feedback signal )
RD & BK are connected to the power, WT & YW are connected to the controlled wiring.
When the SW is closed , the valve open
When the SW is open , the valve closed
BL & GY connect with the valve's fully open signal wiring
YW & WT connect with the valve's fully closed signal wiring.
Suitable Working Voltage::AC110V-230V
Exceeding the working voltage is forbidden